中
◀ Back to feed
Google DeepMind

From spectrum to structure: Identifying molecules with Mass Spec Skills for Google Antigravity

Published 2026-11-25 Collected 2026-11-26 20:00 AI news #ai
Full text

From spectrum to structure: Identifying molecules with Mass Spec Skills for Google Antigravity

Built in collaboration with analytical chemists and using community-developed tools, Mass Spec Skills empowers scientists using Google Antigravity to interpret tandem mass spectra, lay out chemical evidence, and match frontier-level retrieval accuracy even with a lightweight model.

Every sample of blood, soil or plant tissue contains a vast array of small molecules, such as nutrients, hormones, drugs and their breakdown products, pollutants, or bioactive compounds with therapeutic potential. A modern mass spectrometer can detect tens of thousands of these molecular signals in a single drop of sample extract, measuring the masses of charged molecules and, in tandem mass spectrometry (MS/MS), the fragments they break into.

These measurements, however, do not directly reveal the molecular structure. Researchers cannot immediately tell which compound produced a signal and relate it to its biological role or downstream use cases.

To fully map the diversity of small molecules, which remains largely uncharted, researchers need ways to translate mass spectra to molecular structures at scale. The standard approach is to match each spectrum against reference spectra from previously measured molecules. Yet even after a decade of expanding reference libraries, spectral searches annotate on average only about 5% of measured spectra, and 10% for human samples; the rest has been called the "dark matter" of mass spectrometry.

Many of the molecules producing these unannotated signals are already listed in public chemical databases, but their spectra have not been recorded, so there is no reference spectrum to compare against. Elucidating them instead requires inferring the structure directly from the observed fragment ions.

Analytical chemists have a well-tested, step-by-step workflow for narrowing down candidate structures from tandem (MS/MS) spectra: check spectral reference libraries, find the molecular formula and retrieve candidate structures from chemical databases, and then test every candidate against observed fragment peaks.

The tools for each step exist and are openly available, but running the full workflow would take a domain expert a significant amount of time for every single spectrum. Because a single study can produce thousands of spectra, manual analysis cannot keep up, leaving most of these signals unannotated.

Today, we are sharing Mass Spec Skills for Google Antigravity, a suite of domain skills that pair Gemini's chemical reasoning with the ability to run established mass spectrometry tools and query public chemical databases on the user's behalf to fulfil their request. Antigravity runs these skills, combines their results, and reasons about the chemistry, laying out the evidence for a chemist to review.

For molecules that are already catalogued in a database, identification is much faster. For undiscovered molecules, the agent still helps: it narrows down the formula and the parts of the structure supported by the fragments to guide full structure elucidation. A language model cannot do this on its own, since matching fragments to a structure takes precise mass calculations, searches across databases of millions of compounds, and simulations of how bonds break. Pairing Gemini’s reasoning with dedicated chemistry tools brings those steps into one workflow.

Researchers can describe their task and any instrument-specific tolerances in plain language without having to configure each underlying tool. The agent selects and chains the relevant skills, lowering the technical barrier to entry for scientists less familiar with computational tools. From a single prompt, the agent can take an unannotated tandem mass spectrum all the way to a proposed chemical structure and an auditable report (Figure 2).

Each stage of that workflow can also be run on its own for smaller everyday tasks, from cleaning up a noisy recording to annotating peaks or comparing candidate isomers:

From raw spectrum to structure end-to-end

To see how the chemical evidence fits together in practice, consider the negative-mode tandem mass spectrum from the end-to-end run in Figure 2 (precursor [M−H]− at m/z 395.1387; Figure 3).

Negative-ion spectra are traditionally much harder to annotate than positive-ion recordings due to limited reference libraries and less well-characterised fragmentation mechanisms. With spectral library lookup disabled, the agent used SIRIUS to pin down the molecular formula C<sub>20</sub>H<sub>21</sub>ClN<sub>6</sub>O. In the fragmentation tree, the molecule splits cleanly into two complementary halves at m/z 162.1037 ([C<sub>9</sub>H<sub>12</sub>N<sub>3</sub>]−) and m/z 232.0283 ([C<sub>11</sub>H<sub>7</sub>ClN<sub>3</sub>O]−), whose formulas add up to the intact precursor. From the m/z 232.0283 half, sequential neutral losses of HCl and isocyanic acid (HNCO) in both orders form a closed loop indicating a central urea linkage.

With the molecular formula and these fragmentation clues established, the agent retrieved and scored all 845 C<sub>20</sub>H<sub>21</sub>ClN<sub>6</sub>O isomers in PubChem. Several high-scoring candidates, including a fused triazolobenzazepinol isomer (CID 154638626), accounted for 97.7% of the summed fragment intensity across 14 of the 19 preprocessed peaks, so the Gemini-powered agent tested whether they were chemically consistent with the observed losses. The triazolobenzazepinol isomer lacks a urea linkage, leaving it with no route to lose HNCO, and despite carrying a secondary alcohol, the spectrum has only baseline noise at the expected water-loss masses (m/z 377.1281 and m/z 214.0178). Filtering the 845 isomers for structures with a central urea bond that cleaves into the two measured halves ruled out close amide isomers such as the runner-up (CID 55558151; Figure 4) and narrowed the list to five urea regioisomers, where secondary fragments from the chlorophenyl-pyrazole side (m/z 206.0485 and m/z 126.0114) singled out the true molecule (CID 137835447). The verified structure and both rejected non-urea isomers accounted for the same 97.7% of summed fragment intensity, so distinguishing them required testing their fragmentation pathways.

Spectral coverage measures how much peak intensity a candidate matches by mass alone, without testing whether its functional groups and bond connectivity can plausibly form those fragments. Checking candidates against diagnostic neutral losses and bond cleavages, just as an analytical chemist would, lets Antigravity rule out high-scoring mismatches on its own and verify the final structure.

Reliable library identification and verification, even with a lightweight model

Even when a compound's reference spectrum is already stored in a public library, finding and verifying it is harder than simply giving an AI agent internet access. To test how reliably Antigravity handles end-to-end identification and verification, we evaluated it on 100 compounds sampled from the Enamine REAL MS/MS collection in MoNA (with structures also catalogued in PubChem), after filtering out under-fragmented recordings such as intact precursors or dimers that barely broke apart.

We compared three set-ups: (1) Antigravity with no internet access or skills (to test what the models can deduce from the peak list alone), (2) Antigravity with user-permitted internet access to query public libraries and databases on the user's behalf, and (3) Antigravity with that same access plus the Mass Spec Skills, across three models: the lightweight Gemini 3.8 Flash and two frontier models, Gemini 4 Argon and Gemini 4 Carbon.

With no internet access or skills, accuracy remained below 4% across all three models, confirming that they cannot reliably deduce molecular structures from the peak list alone. Giving the agent limited internet access allowed it to query online libraries, but custom search scripts written from scratch proved brittle around precursor windows, adducts, and noisy peaks, causing the frontier models to miss a quarter to a third of the spectra and the lightweight model to miss more than three-quarters.

With the Mass Spec Skills added, all three models identified and verified the exact molecule in around 97% of attempts, with the lightweight model matching the frontier models' accuracy (Figure 5a).

Skills also cut token cost and effort. Without internet or skills, the models used the most tokens per attempt trying to deduce structures from raw peak lists, and with internet access alone they still spent substantial tokens improvising API queries and debugging one-off scripts. With the Mass Spec Skills, the agent in Antigravity calls validated, ready-made skills instead, cutting generated tokens per attempt across every model: by nearly four times on Flash, by half on Argon, and by nearly a fifth on Carbon (Figure 5b).

A collaborative analytical assistant

Antigravity’s Mass Spec Skills pair mass spectrometry tools trusted by the community with transparent agentic reasoning, performing the time-consuming groundwork of spectral interpretation and keeping the chemist in control of decisions requiring scientific judgement.

However, there are some questions that cannot be answered from an LC-MS/MS spectrum at all, such as mirror-image molecules and some closely related isomers. These molecules all break apart in nearly identical ways; telling them apart requires other measurements, such as chromatographic retention time, ion mobility, or NMR.

Genuinely new molecules, including many natural products, are not in any existing database, so Antigravity cannot retrieve or confirm a structure on its own. It does, however, give an informed starting point for chemists, with a predicted formula, peak assignments, and a detailed annotation table.

Scaling automated spectral interpretation from single spectra to full metabolomics studies can help researchers identify far more of the unknown small molecules across human health, environmental science, and natural-product discovery.

Acknowledgements

The Mass Spec Skills are available on Google Antigravity today. Download the Antigravity App and install the Mass Spec plugin to start using these skills.

You can also get started with Mass Spec Skills on Antigravity today as an Enterprise user, by choosing “Use Business Account” and logging into the app with your Google Cloud credentials.

To further advance the pace of research, we’re offering 10,000 scientists the highest usage tier in Google Antigravity free of charge for 6 months (onboarded on a rolling basis), subject to eligibility, capacity, and selection. Applications are now open.

Joao Madeira Araujo, Andrew Campbell, Valentin De Bortoli, Antoine Dedieu, Arnaud Doucet, Julian Eisenschlos, Romu Elie, Doug Fritz, Gena Hong, Dan Horgan, Victoria Johnston, Anna Koivuniemi, Ira Korshunova, Agata Laydon, Vlad Mnih, Filip Radlinski, Sukhdeep Singh, Artem Sobolev, Lexi Walker and the Biocompatibility team.

Source
Title
From spectrum to structure: Identifying molecules with Mass Spec Skills for Google Antigravity
Author
Robert Brunck, Stefan Ganscha, Swaroop Guntupalli, Dariusz Lasecki, Gabriella Marfani, Jack Mason, Hussain Masoom, Rose Mirshafian, Eliseo Papa, Zoi Tsangalidou
Site
Google DeepMind
Published
2026-11-25
Collected
2026-11-26 20:00 · 2026-11-26-20-ai.json
Link
https://deepmind.google/blog/interpreting-mass-spectra-with-google-antigravity/
Open original ↗

Reposted. Will be removed on request. All rights belong to the original author.

More from this batch

20:00batch · 2026-11-2612 items
>

Migrating our Messages API to Rust

官方工程博文写明,这是客户和 Claude Code、Cowork 访问 Claude 的主接口;从 2024 年初到 2026 年秋,流量大约增长了 1800 倍。Claude 大约用一周写出核心请求路径的第一版,但难处在验证:Python 服务还在继续改、模型输出不是确定性的…

Anthropic
>

OpenAI 承认 GPT-6.2 上线时计费有误:修复后 Astra 会大约快 40%、Sol 大约快 25% 碰到用量上限(11 月 26 日)

ChatGPT 产品负责人 Thibault Sottiaux 在 X 上以团队口吻说,GPT-6.2 上线时错误地给大多数用户的 Astra 和 Sol 用量打了折,现已修好,同样工作会占用更多套餐额度。和上周比,Astra 大约会快 40%、Sol 大约快 25% 碰到上限;…

OpenAI / TechCrunch
>

OpenAI 开始把 ChatGPT 的 Chat 和 Work 合成一套用量:最频繁的用户可能会更快撞上限(11 月 25 日)

TechCrunch 引述 OpenAI 发言人:公司已向一小部分 Pro 用户推出合并后的 Chat 与 Work 体验,两套功能将共用一个计量表;Instant 模型不计入、用完额度后也仍可继续用 Instant。发言人说,大多数用户预计不会更频繁地等到重置,但最重度的一小部…

TechCrunch
>

42 state AGs are trying to stop Character.AI from selling users’chats

The Verge 报道,一个跨党派的 42 州检察长联盟指责 Character.AI 计划在破产拍卖中出售超过 2100 万个美国账户的私聊历史,其中超过 210 万个登记为未成年人账户,且没有要求买家遵守现有隐私政策、也没有给用户删除数据的途径。首名竞标方 11 月 13 …

The Verge
>

报道称英伟达已要求合作伙伴停止向马来西亚、新加坡、泰国和印度尼西亚发货服务器(11 月 26 日)

The Decoder 写道,在美国收紧对「经东南亚云再进入中国」的出口管制后,英伟达已告诉 Dell、Supermicro 等合作伙伴,停止向这四国发运服务器。这是媒体转述,不是英伟达官方博文;具体范围、例外和生效时间要以原报道和后续官方说明为准。

The Decoder
>

微软公布 ARTEX:一个几乎不用人盯着、用专用智能体自动跑网络攻击的框架(11 月 26 日)

The Decoder 根据微软披露写道,ARTEX 自 2026 年 7 月以来被广泛使用,由国家背景的攻击方用专门智能体自动执行攻击,人工介入很少。文章介绍的是技术架构,值得安全团队对照自己的检测和响应是否跟得上这种自动化。细节和归属仍以微软原文为准。

The Decoder
>

标普考虑下调英伟达信用评级,理由包括治理和「关键人」风险(11 月 25 日)

TechCrunch 报道,信用评级机构标普可能把英伟达的评级下调到 AA-(其第四高的等级),关注点包括治理,以及过度依赖黄仁勋个人的「关键人」风险。这还只是在考虑,不是已经降级;和股价、出口管制是同一条故事线里的信用视角。

TechCrunch
>

FCC 批准 SpaceX「Starmind」计划:最多可部署 100 万颗搭载 AI 芯片的卫星(11 月 25 日)

The Verge 报道,美国联邦通信委员会授权 SpaceX 在「Starmind」计划下部署最多 100 万颗配备 AI 芯片的卫星,用来在太空做数据中心式计算。这是监管批准,不等于已经发射或建成;后续还有轨道、频谱和报废处置等约束。

The Verge
>

Dario Amodei 回应「把社会治理交给 AI」的说法,称这种指责「荒谬」(11 月 25 日)

TechCrunch 和 The Decoder 都报道了 Anthropic CEO 对近期舆论的回应。The Decoder 引他的话说,把治理交给 AI「是个坏主意」;TechCrunch 写他称「放弃人类控制、交给 AI」这类指责是荒谬的。这是对 Axios 等报道之后舆…

TechCrunch / The Decoder
>

纽约禁止销售 AI 聊天玩具五年,Common Sense Media 称现有产品安全问题多(11 月 25 日)

TechCrunch 报道,纽约已禁止 AI 聊天玩具,禁令为期五年;同时引述 Common Sense Media 的新研究,指现有产品存在不当内容和情感依赖等风险。这是州一级的儿童产品监管,企业如果做面向未成年人的对话产品,需要单独看各地的生效时间。

TechCrunch
>

亚马逊与 Meta 据报在谈,是否解除对 Muse 购物智能体的封锁(11 月 25 日)

TechCrunch 和 The Verge 都引述报道:亚马逊今年 9 月把 Meta 的 Muse 购物智能体挡在站外后,双方在讨论是否解禁,焦点包括广告分成和搜索结果由谁控制。这还是在谈判,不是已经恢复接入。

TechCrunch / The Verge
>

黄仁勋复职之后,Megaspeed 芯片流向问题仍然待查(11 月 25 日)

TechCrunch 写,调查的核心问题仍是:英伟达当时是否清楚这些芯片最终去了哪里,以及黄仁勋与 Megaspeed 高管的关系,是否让公司有理由怀疑对方的保证。这是复职新闻的后续,不是结案说明,目前公开的仍是调查问题和媒体梳理。

TechCrunch